Is suitable for use in any system where a digital output to a computer or logger is required.
The Visibility Sensor operates in temperatures ranging from -50º C to +60º C. For operation below -32º C the heated version is recommended.
The Visibility Sensor is also supplied with a stainless steel mounting kit.
More information on: http://www.biral.com/meteorological-sensors/visibility-and-present-weather
| Visibility range |
Standard 10m to 75km Other ranges available at time of order 10m-2km, 10m-20km, 10m-32km, 10m-50km |
| Visibility error |
<=1.3% at 600m <=1.8% at 1500m <=2.0% at 2km <=8.3% at 15km <=10.5% at 30km |
| Measurement principle | forward scatter meter with 39° to 51° angle |
| Output data rate | serial 10 to 300sec (selectable) |
| Serial outputs |
RS232 as standard RS422/RS485 as an option |
| Sensor power |
12VDC, 24VDC, 120VAC, 240VAC |
| Hood heating power |
sensor 6W hood heaters 30W |
| Operating temperature | -50° to +60° |
| Operating humidity | 0 - 100%RH |
| Protection rating | IP66 |
| Material | Hard coat anodised, dip brazed alluminium |
| Weight |
4.9kg DC sensors 6.1kg AC sensors |
| Lenght | 751mm |
| Lifetime | >10 years |
| User confidence check | 6 month recommended |
| Window cleaning | automatic compensation and warnings |
| Field calibration | with optional calibration kit |
| Included with sensor | pole mounting kit (1 x U-bolt), 6m power and data cables, user manual and calibration certificates |
| Accessories (optional) | alternative lengths power and data cable, calibration kit, hard shell transport case, ALS-2 ambient light sensor |
| Certification and Compliance | CE certified, EMC compliance with EN61326-1997, 1998, 2001, RoHS and WEEE compliant |