Precipitation sensor "rain[e]"
Rain[e] is a compact weighing precipitation sensor made by the Lambrecht Meteo company.
The first of a new kind.
Latest weighing technology combined with a self-emptying precision tipping bucket allows the rain[e] a high resolution and high precision at a very small construction volume. Already the first drop will be measured! The rain[e] is ideal to setup new measurement networks as well as addition to an existing rainfall measurement network.
• amazing resolution and accuracy
• checking of sensors with tipping
bucket and other weighing systems
• compact and robust construction
with a very low weight
• all-metal housing, weatherproof and
durable
• best connectivity by several interfaces
• installation
Rain[e], unheated Professional Line |
Id-No. 00.15184.000 000 Rain[e] Weighing precipitation sensor |
---|---|
Measuring principle: | weighing with automatic self emptying |
Operating temperature: | 0...+70 °C (unheated) |
Collecting area: | 200 cm² |
Amount measuring range: | without limitation (0.005…∞ mm) |
Amount resolution: | 0.001 mm (pulse output: 0.01 mm) |
Amount accuracy: | ± 0.1 mm or ± 1 % at < 6 mm/min and ± 2 % at > 6 mm/min |
Intensity range: | 0…20 mm/min resp. 0…1200 mm/h |
Intensity resolution: | 0.001 mm/min resp. 0.001 mm/h |
Intensity accuracy: | ± 0.1 mm/min resp. ± 6 mm/h |
Standards: |
WMO-No. 8 • VDI 3786 Bl. 7 • EN 61000-2, -4 • EN 61000-4-2, -3, -4, -5, -6, -11 NAMUR NE-21 |
Protection class weighing cell: | IP67 |
Current consumption: |
max. 45 mA at 24 V power supply and analogue output • typ. 6.5 mA at 24 V power supply and pulse output · typ. 10.5 mA at 12 V |
Supply voltage: | 9.8...32 V DC |
Signal outputs: |
· SDI-12 • RS-485 (SDI-12 protocol, ASCII protocol, TALKER protocol) · 2 Pulse-Outputs for linearised, bounce-free output signal · Status-Output (confi gurable, e.g. rain yes/no or heating on/off ) · Analogue output 0/4...20 mA (0...2.5/5V) |
rain[e], heated | Id-No. 00.15184.400 000 |
Data like rain[e] 00.15184.000 000, but in addition with controlled 2-circuit-heating | |
Target temperature (heating): | +2 °C funnel surface temperature |
Heating power: | 80 W (funnel) • 60 W (outlet/ tipping bucket) |
Supply voltage: | 24 V DC / 2 heating circuits 80 W and 60 W |
Operating temperature: | -40...+70 °C (no icing, no snowdrift) |
Title | Description | Filename |
---|---|---|
Rain[e] datasheet | rain_e_datasheet_en.pdf |
For more information


We are satisfied with the instrument, thank you for quick delivery.
We think it is the best Handheld station available now.
Aki Paananen - MeteoExpert